Custom Modbus TCP and Remote Values
Part of the compatibility overview, which lists every selectable Mains type.
Custom Modbus TCPreads any Modbus TCP meter with a register map stored on the station. The map is prepared by eCharge support for the specific meter; contact support with the meter's Modbus register documentation. Battery registers cannot be used with this type; it delivers grid values only.Remote Valuestakes the grid values from an external system that writes them to the station over the REST API, and needs no meter at all. Battery power and state of charge can be pushed as well. Values must arrive at least every 10 seconds; otherwise the station treats the meter as unavailable and regulates with 0 W. Per-phase powers for L2 and L3 are currently not taken over from the pushed values. Ask eCharge support for the field format.