OCPP 1.6J
Salia charging stations connect to a backend (Central System) with OCPP 1.6J, that is OCPP 1.6 over WebSocket with JSON. This page describes which parts of the protocol the station implements and where it deviates from what a backend may expect. The fault codes the station sends are listed on OCPP Error Codes.
Applies to firmware 2.5.0 and later on all charging stations with the Salia
controller. Each station has one connector (connector 1); connector 0
stands for the station as a whole.
Connection
| Topic | Behaviour |
|---|---|
| Protocol | OCPP 1.6J, WebSocket subprotocol ocpp1.6. SOAP and OCPP 2.0.1 are not supported. |
| Backend URL | ws:// or wss://. The URL is used exactly as entered, so it has to contain the charge point ID, for example wss://backend.example.com/ocpp/CP-0001. A changed CentralSystemURI takes effect after a restart. |
| TLS | wss:// uses TLS 1.2. The server certificate, including the host name, is only checked when Verify CERT is enabled in the OCPP settings of the web UI. The option is off in the factory setting; without it any server certificate is accepted. |
| Authentication | HTTP Basic Auth with user name and password. The credentials are set in the station's web UI; they cannot be changed over OCPP (AuthorizationKey is not supported). Client certificates are not supported. |
| Response time | The backend has to answer every request within 60 seconds. Otherwise the station closes the connection and connects again. |
| Time | The station takes its time from BootNotification and Heartbeat (and NTP, if configured). Calibration-law (Eichrecht) stations refuse transactions until the clock is set. Other stations also start transactions with an unset clock (allowTxWithInvalidTime); their timestamps are then wrong. |
| BootNotification | chargePointVendor and chargePointModel (up to 20 characters each), chargePointSerialNumber and chargeBoxSerialNumber (if set; up to 25 characters each), firmwareVersion, meterType, meterSerialNumber; iccid and imsi on stations with a mobile modem. |
| Registration | The station starts transactions, online or offline, only after the backend in CentralSystemURI has accepted a BootNotification at least once. Changing CentralSystemURI discards transactions that were not yet sent to the previous backend. |
Feature profiles
The configuration key SupportedFeatureProfiles reports
Core,FirmwareManagement,LocalAuthListManagement.
| Profile | Support |
|---|---|
| Core | Supported, limits below. |
| Firmware Management | Supported. |
| Local Auth List Management | Supported, full updates only. |
| Reservation | Not supported. ReserveNow is answered with Rejected. |
| Smart Charging | Not reported. SetChargingProfile is accepted in a limited form, see below. |
| Remote Trigger | Not reported. TriggerMessage works for some messages, see below. |
The extensions of the OCPP 1.6 Security Whitepaper (signed firmware update,
certificate management, security events, GetLog) are not implemented.
While a restart is pending (after Reset or a firmware installation) the
station answers most requests with a CALLERROR GenericError.
Messages
Core
| Message | Direction | Notes |
|---|---|---|
Authorize | Station → backend | Sent for cards that are not authorized locally, while online. |
BootNotification | Station → backend | After Pending or Rejected the station retries after the interval from the answer. |
ChangeAvailability | Backend → station | Connector 0 and 1. Inoperative while the connector is Preparing, Charging or Finishing is answered with Scheduled and applied when the vehicle is unplugged. Kept across a restart. |
ChangeConfiguration | Backend → station | Keys see Configuration keys. Unknown keys: NotSupported; read-only keys: Rejected. |
ClearCache | Backend → station | Accepted if the authorization cache is enabled, otherwise Rejected (factory setting). |
DataTransfer | Both | Vendor-specific. A DataTransfer from the backend with an unknown vendorId is answered with UnknownMessageId. On calibration-law stations the station sends the meter's public key after BootNotification (vendorId generalConfiguration, messageId setMeterConfiguration); this can be switched off with sendMeterPublicKeyOnBootNotification. |
GetConfiguration | Backend → station | All keys or the requested ones; unknown keys in unknownKey. |
Heartbeat | Station → backend | When no other message was sent for HeartbeatInterval seconds. |
MeterValues | Station → backend | Only during a transaction, always with transactionId. Not stored while offline. |
RemoteStartTransaction | Backend → station | Connector 1. A chargingProfile in the request is ignored. The vehicle has to be plugged in within ConnectionTimeOut. Rejected if the station is not registered, the connector is not Available, Preparing or Finishing (for example Faulted), the meter is not ready, a storage fault is active, 336 transactions are waiting to be sent, another authorization is pending, or the clock is unset on a calibration-law station. |
RemoteStopTransaction | Backend → station | Stops with reason = Remote. Rejected if the transactionId is unknown or the station or connector is Unavailable. |
Reset | Backend → station | Soft and Hard both stop a running transaction and restart the whole station after about 10 seconds. Rejected during a firmware update. |
StartTransaction | Station → backend | Stored on the station before it is sent and sent again after a connection loss. |
StatusNotification | Station → backend | Available, Preparing, Charging, Finishing, Unavailable, Faulted. SuspendedEV and SuspendedEVSE are not used: a paused session stays Charging. Notifications for connector 0 and 1 are sent at most once every 10 seconds together and carry the status at that moment, so a status that lasts shorter can be skipped. Identical notifications are not repeated, except after a reconnect. |
StopTransaction | Station → backend | Reasons EmergencyStop, EVDisconnected, HardReset, SoftReset, Local, PowerLoss, Remote, UnlockCommand, DeAuthorized, Other. idTag is not sent. |
UnlockConnector | Backend → station | Socket variants only; on stations with a fixed cable the answer is NotSupported. A running transaction is stopped (reason = UnlockCommand). The answer is sent once the lock has opened (Unlocked) or after 20 seconds (UnlockFailed); the backend's response timeout must be longer than 20 seconds. |
Firmware Management
| Message | Direction | Notes |
|---|---|---|
UpdateFirmware | Backend → station | location (HTTP or HTTPS URL of the firmware file), retrieveDate, retries and retryInterval. The download starts at retrieveDate while the station is connected. The station installs the file and restarts. A second UpdateFirmware during a running update is acknowledged and ignored. |
FirmwareStatusNotification | Station → backend | Downloading, Downloaded, DownloadFailed, Installing, InstallationFailed, Installed (after the restart). |
GetDiagnostics | Backend → station | Uploads a log archive (.tar.gz) by FTP, FTPS, HTTP or HTTPS. With HTTP(S) the file is sent as POST to <location>/<fileName>. startTime and stopTime are ignored. |
DiagnosticsStatusNotification | Station → backend | Uploading, Uploaded, UploadFailed. |
Local Auth List Management
| Message | Direction | Notes |
|---|---|---|
GetLocalListVersion | Backend → station | -1 while LocalAuthListEnabled is false. |
SendLocalList | Backend → station | updateType Full only; Differential is answered with NotSupported, as is any update while LocalAuthListEnabled is false. Up to 10,000 entries. |
Smart Charging (limited, not reported)
| Message | Direction | Notes |
|---|---|---|
SetChargingProfile | Backend → station | Accepted only with chargingProfilePurpose ChargePointMaxProfile (connector 0) or TxProfile, chargingProfileKind Relative, chargingRateUnit A, stackLevel 0 and exactly one schedule period with startPeriod 0, without duration and minChargingRate. Other profiles are answered with NotSupported. A ChargePointMaxProfile for connector 1 is Rejected, as is a TxProfile for a transactionId other than the running one. ChargePointMaxProfile is kept across a restart; TxProfile ends with the transaction. |
ClearChargingProfile | Backend → station | By connector, profile ID or purpose. Unknown if no profile matches. |
GetCompositeSchedule | Backend → station | Not supported (Rejected). |
Remote Trigger (partial, not reported)
TriggerMessage is accepted for BootNotification, Heartbeat and
StatusNotification. MeterValues, DiagnosticsStatusNotification and
FirmwareStatusNotification are answered with NotImplemented.
Configuration keys
The Factory setting column shows the values of a station on firmware 2.5.0
as delivered. Keys marked restart are stored at once and answered with
RebootRequired; they take effect after the next restart.
A firmware update sets MeterValuesSampledData back to the factory list.
Saving the settings in the web UI sets both LocalAuthListEnabled and
LocalAuthorizeOffline to the value of the Offline Authentication
option, including values set by the backend. Stations updated from older
firmware keep their previous values.
| Key | Access | Factory setting | Takes effect |
|---|---|---|---|
AllowOfflineTxForUnknownId | read/write | false | immediately |
AuthorizationCacheEnabled | read/write | false | restart |
AuthorizeRemoteTxRequests | read/write | false | immediately |
ClockAlignedDataInterval | read/write | 0 | restart |
ConnectionTimeOut | read/write | 60 | immediately |
HeartbeatInterval | read/write | from BootNotification (600 before) | immediately, not stored; values up to 2 are rejected |
LocalAuthListEnabled | read/write | false | restart |
LocalAuthorizeOffline | read/write | false | immediately |
LocalPreAuthorize | read/write | false | immediately |
MeterValuesAlignedData | read/write | empty | restart |
MeterValuesSampledData | read/write | Energy.Active.Import.Register, Power.Active.Import, Power.Active.Import.L1–L3, Current.Import.L1–L3, Voltage.L1-N–L3-N | next transaction |
MeterValueSampleInterval | read/write | 60 | next transaction |
StopTransactionOnInvalidId | read/write | true | immediately |
StopTxnAlignedData | read/write | empty | next transaction |
StopTxnSampledData | read/write | empty | next transaction |
TransactionMessageAttempts | read/write | 3 | restart |
TransactionMessageRetryInterval | read/write | 30 | restart |
WebSocketPingInterval | read/write | 10 | immediately |
CentralSystemURI | read/write | as configured | restart; rejected during a transaction |
ChargeProfileMaxStackLevel | read only | 0 | |
ChargingScheduleAllowedChargingRateUnit | read only | Current | |
ChargingScheduleMaxPeriods | read only | 1 | |
ConnectorPhaseRotation | read only | Unknown | |
GetConfigurationMaxKeys | read only | 10 | |
LocalAuthListMaxLength | read only | 10000 | |
MaxChargingProfilesInstalled | read only | 2 | |
MeterValuesAlignedDataMaxLength | read only | 27 | |
MeterValuesSampledDataMaxLength | read only | 27 | |
NumberOfConnectors | read only | 1 | |
ResetRetries | read only | 0 | |
SendLocalListMaxLength | read only | 10000 | |
StopTransactionOnEVSideDisconnect | read only | true | |
StopTxnAlignedDataMaxLength | read only | 27 | |
StopTxnSampledDataMaxLength | read only | 27 | |
SupportedFeatureProfiles | read only | see above | |
SupportedFileTransferProtocols | read only | FTP,FTPS,HTTP,HTTPS | |
UnlockConnectorOnEVSideDisconnect | read only | true |
Vendor-specific keys:
| Key | Access | Factory setting | Meaning |
|---|---|---|---|
rfidStopTransaction | read/write | false | true: the card that started a session can stop it at the station. Takes effect after a restart. |
rfidRequiresEvPresent | read/write | true | true: cards are only read while a vehicle is plugged in. Takes effect after a restart. |
useAsTimeSource | read/write | true | Set the clock from BootNotification and Heartbeat. |
allowTxWithInvalidTime | read/write | true | Allow transactions before the clock is set (never on calibration-law stations). |
allowLocalChargingAlways | read/write | false | true: every card is accepted locally, the answer to StartTransaction is ignored and RemoteStartTransaction is always Rejected. |
bootNotificationOnReconnect | read/write | false | Send BootNotification after every reconnect. |
webSocketPingTimeout | read/write | 120 | Seconds without a WebSocket pong before the connection is re-established. |
forwardCredentials | read/write | empty | Host for which the Basic Auth credentials are also used for firmware and diagnostics URLs. |
ftpTryTLSUpgrade | read/write | false | Try explicit FTPS for diagnostics uploads. |
calibrationLawFormat | read/write | empty | Format of the signed meter values: empty, OCMF,plain or OCMF,hex. |
sendMeterPublicKeyOnBootNotification | read/write | true | Send the meter's public key by DataTransfer after BootNotification. |
StopTransactionSignatureFormat | read only | MR | Signed meter values: start and end in one OCMF data set. |
Meter1PublicKey | read only | from the meter | Public key of the calibration-law meter. |
vendorId | read only | com.in-tech.smartcharging | vendorId of the station for DataTransfer and StatusNotification. |
Authorization
- While online, cards known locally (authorization cache or local list)
start charging at once if
LocalPreAuthorizeistrue; all other cards are checked withAuthorize. - Offline, cards from the cache or the local list are accepted only if
LocalAuthorizeOfflineistrue. If it isfalse, every card counts as unknown, and unknown cards are accepted only ifAllowOfflineTxForUnknownIdistrue. - A card stops a running session at the station only if
rfidStopTransactionistrue, and only the card that started it. - If the backend answers
StartTransactionwith a status other thanAccepted, or with anexpiryDatein the past, the station stops the session (reason=DeAuthorized). KeepStopTransactionOnInvalidIdattrue: withfalsecharging is stopped as well, but noStopTransactionis sent, so the transaction stays open in the backend.
Connection loss and power loss
- Connection loss. Charging continues.
StartTransactionandStopTransactionare stored on the station and sent once the connection is back; a transaction started offline receives itstransactionIdthen. Up to 336 transactions are stored; when that many are waiting, no new transaction starts until the connection is back.MeterValues,StatusNotification,Heartbeatand status notifications for firmware and diagnostics are not stored. After reconnecting the station sends the current status of connector 0 and 1. - Power loss. A transaction that was running when the power failed is
ended after the restart with
reason=PowerLoss;meterStopandtimestampare taken after the restart. The vehicle has to be authorized again. The same applies to any restart that was not requested byReset. - Firmware update. After a successful installation the station restarts
at once; a running transaction is then ended with
reason=PowerLoss. Schedule updates outside charging sessions.
Signed meter values
On calibration-law (Eichrecht) stations StopTransaction carries the
signed meter values in transactionData: a sampled value with context
Transaction.End and format SignedData holding the OCMF data set with
start and end of the transaction. The meter's public key is available in
Meter1PublicKey.
Products
The OCPP implementation is the same on all charging stations with the Salia controller.