A Salia charging station reports faults to the backend in the
StatusNotification message of OCPP 1.6J. The errorCode field carries the
standard OCPP code; for most faults the vendorErrorCode field names the
exact cause. This page lists every combination the station sends.
Applies to firmware 2.5.0 and later on all charging stations with the Salia
controller.
How faults are reported
One fault at a time. For each connector the station reports only the
fault with the highest priority. The tables below are in priority order.
A fault further down is reported with the next StatusNotification
after the one above it is cleared.
Connectors. Connector 1 is the charging point. Connector 0 stands
for the whole station and reports Faulted for the station-wide faults
marked 0 and 1 below and for LocalListConflict.
vendorId. When a vendorErrorCode is set, the message also carries
vendorId. The default is com.in-tech.smartcharging. The info field is
not used.
Status. Most faults set the connector to Faulted. The faults marked
current status report the error code with the status the connector has
at that moment, for example Charging, and do not stop the transaction.
Reconnect. After the connection to the backend is (re)established the
station sends a StatusNotification for connector 0 and connector 1, so a
fault that is still present is reported. A fault that occurred and cleared
while the station was offline is not reported.
Stopping a transaction. Where a fault ends a running transaction, the
station sends StopTransaction with reason = Other. The emergency
shutdown is the exception: it uses reason = EmergencyStop.
Reset Hard below means Reset.req from the backend (Hard or
Soft; both restart the whole station), or switching the station off and
on again on site.
Fault list
Contactor
errorCode
vendorErrorCode
Connector
Meaning
Status
Effect on charging
Cleared
Recommended action
PowerSwitchFailure
–
1
The feedback of the power contactor does not match the switching command.
Faulted
A running transaction is stopped and the charging point is switched off.
By Reset Hard at the latest.
Reset Hard. If the fault comes back, especially under load, have a qualified electrician check the supply line, the N/PE connection and the contactor, and contact eCharge service.
Plug lock (socket variants only)
errorCode
vendorErrorCode
Connector
Meaning
Status
Effect on charging
Cleared
Recommended action
ConnectorLockFailure
PlugLockMotorCapNotCharged
1
The energy store of the lock motor is not charged after the charging time.
Faulted
A running transaction is stopped.
By Reset Hard at the latest.
Reset Hard. If the fault comes back, contact eCharge service (plug lock hardware).
ConnectorLockFailure
PlugLockMotorUnexpectedOpen
1
The plug lock opened unexpectedly. The station drives the lock fully open.
Current status
The transaction is not stopped.
By Reset Hard at the latest.
Unplug and re-insert the cable, check the socket for foreign objects or damage, Reset Hard. If the fault comes back, contact eCharge service.
ConnectorLockFailure
PlugLockMotorUnexpectedClose
1
The plug lock closed unexpectedly.
Faulted
A running transaction is stopped.
By Reset Hard at the latest.
As above.
ConnectorLockFailure
PlugLockCannotLock
1
The lock does not reach the locked position, even after several attempts.
Faulted
A running transaction is stopped.
By Reset Hard at the latest.
Check that the plug is fully inserted, then as above.
ConnectorLockFailure
PlugLockCannotUnlock
1
The lock does not reach the unlocked position; the cable may not come out.
Faulted
A running transaction is stopped.
By Reset Hard at the latest.
Send UnlockConnector or Reset Hard. If the cable still cannot be removed, a qualified electrician releases it manually; contact eCharge service.
ConnectorLockFailure
PlugLockMotorDriverFault
1
The motor driver of the plug lock reports a fault.
Faulted
A running transaction is stopped.
By Reset Hard at the latest.
Reset Hard. If the fault comes back, contact eCharge service (plug lock hardware).
ConnectorLockFailure
unknown
1
A plug lock fault that is not classified further.
Faulted
A running transaction is stopped.
By Reset Hard at the latest.
As for PlugLockMotorUnexpectedOpen.
Energy meter
errorCode
vendorErrorCode
Connector
Meaning
Status
Effect on charging
Cleared
Recommended action
PowerMeterFailure
CommunicationError
1
The energy meter does not answer, or was not found at start-up.
Faulted
Energy delivery stops and no new transaction can start. A running transaction stays open until the vehicle is unplugged.
Automatically, as soon as the meter answers again.
Reset Hard. If the fault stays, have a qualified electrician check the supply and the bus wiring of the meter; contact eCharge service.
PowerMeterFailure
InternalError
1
A meter value or signed meter value request was not answered within 11 seconds.
Faulted
A running transaction is stopped, possibly without a signed data set.
Reset Hard.
Reset Hard. If the fault comes back, contact eCharge service.
PowerMeterFailure
IdleMeterError
1
Calibration-law (Eichrecht) variants only: unexpected state change of the meter outside a transaction.
Faulted
A running transaction is stopped.
Reset Hard.
Reset Hard. If the fault comes back, contact eCharge service.
PowerMeterFailure
ActiveMeterError
1
Calibration-law (Eichrecht) variants only: unexpected state change of the meter during a transaction.
Faulted
A running transaction is stopped, possibly without a signed data set.
Reset Hard.
Reset Hard. If the fault comes back, contact eCharge service.
RFID reader
errorCode
vendorErrorCode
Connector
Meaning
Status
Effect on charging
Cleared
Recommended action
ReaderFailure
–
1
The RFID reader does not answer (only when RFID is enabled).
Current status
Charging is not interrupted. Cards cannot be read; RemoteStartTransaction still works.
Automatically, as soon as the reader answers again.
Reset Hard. If the fault stays, contact eCharge service (RFID module).
Residual current monitoring
errorCode
vendorErrorCode
Connector
Meaning
Status
Effect on charging
Cleared
Recommended action
GroundFailure
RcdGroundFailure
1
The residual current monitor detected a residual current.
Faulted
A running transaction is stopped.
By Reset Hard at the latest.
Unplug the vehicle and test with another vehicle. If the fault occurs with one vehicle only, have the vehicle and its cable checked. If it occurs with every vehicle, have a qualified electrician check the installation.
GroundFailure
SpuriousRcdError
1
The residual current monitor is in an unexpected state.
Faulted
A running transaction is stopped; the charging point stays blocked.
Reset Hard.
Reset Hard. If the fault comes back, contact eCharge service.
GroundFailure
RcdTestError
1
The periodic self-test of the residual current monitor failed.
Faulted
A running transaction is stopped; the charging point stays blocked.
Reset Hard.
Reset Hard. If the fault comes back, contact eCharge service (residual current module).
Other faults
errorCode
vendorErrorCode
Connector
Meaning
Status
Effect on charging
Cleared
Recommended action
OtherError
EmergencyShutdown
0 and 1
The emergency shutdown input of the station is triggered (external shutdown).
Faulted
A running transaction is stopped with reason = EmergencyStop; the charging point is blocked.
Automatically, as soon as the input is released.
Find the cause of the external shutdown on site. The station returns to Available by itself afterwards.
OtherError
RcdRecloserFailure
1
Only with a configured auto-recloser: the recloser reports a fault.
Current status
Charging is not interrupted by OCPP.
Automatically, as soon as the recloser no longer reports a fault.
Have a qualified electrician check the recloser and the residual current device.
OtherError
Persistence… (see below)
0 and 1
Internal storage fault: the local transaction database of the station cannot be read or written. The code names the operation that failed.
Connector 0: Faulted. Connector 1: Faulted if the fault occurs during operation; if the storage cannot be opened at start-up, connector 1 keeps its normal status (e.g. Available).
The charging point is blocked; no new transaction can start.
Reset Hard.
Reset Hard. If the fault comes back after the restart, install the current firmware and contact eCharge service.
OtherError
CpShortCircuit
1
Short circuit on the control pilot line (cable or vehicle).
Faulted
A running transaction is stopped.
Automatically, as soon as the short circuit is gone.
Unplug the vehicle and check the cable and the vehicle plug for damage. If the fault occurs without a vehicle, contact eCharge service.
OtherError
ProximityNoCable
1
Socket variants only: no charging cable is detected any more during charging.
Current status, sent once
Energy delivery stops; the transaction stays open until the vehicle is unplugged.
No clearing notification; the next StatusNotification (status change) carries NoError.
Check the charging cable or use another one.
OtherError
ProximityInvalid
1
Socket variants only: invalid coding resistor in the charging cable.
Current status, sent once
Energy delivery stops; the transaction stays open until the vehicle is unplugged.
No clearing notification; the next StatusNotification (status change) carries NoError.
Use a cable that complies with IEC 61851.
OtherError
ProximityChanged
1
Socket variants only: the coding resistor of the cable changed during charging.
Current status, sent once
Charging continues.
No clearing notification; the next StatusNotification (status change) carries NoError.
Check the cable for damage or a loose contact, or replace it.
LocalListConflict
–
0
The backend's answer (idTagInfo) contradicts the local authorization list of the station.
Faulted (connector 0 only)
No effect on charging.
When a SendLocalList is accepted.
Send the local authorization list again with SendLocalList, updateType = Full.
The storage fault codes are PersistenceOpenFailed,
PersistencePrepareFailed, PersistenceFinalizeFailed,
PersistenceCountError, PersistenceClearError, PersistenceUpdateFailed,
PersistenceDropFailed, PersistenceTransactionFailed,
PersistenceCreateFailed, PersistenceInsertFailed,
PersistenceDeleteFailed, PersistenceUnlinkDenied,
PersistenceReadOnly, PersistenceInvalidType,
PersistenceTooManyTransactions and PersistenceNoInsertRowId. They all have the same meaning and the same
recommended action.
Proximity faults are sent only while the station is connected to the
backend, at most once every 10 seconds, and are not queued while the station
is offline.
Codes the station does not send
The following OCPP 1.6 error codes are not used: EVCommunicationError,
HighTemperature, InternalError, OverCurrentFailure,
OverVoltage, ResetFailure, UnderVoltage, WeakSignal.