Thermal monitoring, RCD status, ventilation, emergency shutdown, and plug lock state.
Current temperature in millidegrees Celsius. Example: "49896" = 49.896°C.
"49896"
Temperature retrieved
Max temperature retrieved
Min temperature retrieved
Returns "1" if emergency shutdown is active, "0" if normal.
"1"
"0"
Emergency shutdown status retrieved
RCD feedback availability retrieved
Returns "1" if RCD is OK, "0" if tripped.
RCD state retrieved
Returns "1" if contactor is closed, "0" if open.
Contactor state retrieved
Returns "0" for no error.
Contactor error status retrieved
Returns "1" if locked, "0" if unlocked.
Plug lock state retrieved
Plug lock error status retrieved
Returns the cable's current limit in Amperes, or "-1" if no cable is connected or the cable doesn't report a limit (Type 2 fixed cable).
"-1"
Cable current limit retrieved
Diode presence retrieved
Returns "running" or "stopped".
"running"
"stopped"
Modbus status retrieved